PRODUCT > 장비 > SOCOREX

  • 제품명 : Acura® manual 825

  • adjustable volume micropipettes
    Equipped with a precision setting mechanism,
    the line is continuously adjustable down to
    a very fine volume resolution.
    Single-handed volume setting easy when
    other hand busy.
    Click stops, together with freely rotating
    Smartie plunger button cap secure setting
    stability while pipetting.
    A total of 8 micropipettes covering
    volumes from 0.1 to 1000 µL.


    Acura® manual Triopack
     Three Acura® manual 825 / 835 pipettes
     Qualitips® samples
     QC certificates
     Operating instructions
    There are nine different packs available:
    C : 2 - 10 - 50 µL
    J : 2 - 20 - 200 µL
    M : 10Y - 50 - 200 µL
    O : 10 - 100 - 1000 µL
    P : 10Y - 100 - 1000 µL
    S : 20 - 200 - 1000 µL
    T : 50 - 200 - 1000 µL
    V : 100 µL - 1000 µL - 5 mL
    Y : 1000 µL - 5 mL - 10 mL
    Ordering and performance information
    Individual units
    Inaccuracy (Rel. err.%) Imprecision (CV %)
    Cat. No. Vol. µL Div. µL Min. vol. Mid. vol. Max. vol. Min. vol. Mid. vol. Max. vol. Tip style
    825.0002 0.1 - 2 0.002 <±6.0%1) <± 4.0% <± 2.0% <5.0%1) < 3.3% < 1.5% ultra 10 µL
    825.0010 0.5 - 10 0.01 <±2.5%2) <± 1.8% <± 1.0% <1.8%2) < 1.2% < 0.5% ultra 10 µL
    825.0010Y 1 - 10 0.01 <± 2.5% <± 1.8% <± 1.0% < 2.5% < 1.6% < 0.7% 200 µL
    825.0020 2 - 20 0.02 <± 2.5% <± 1.8% <± 1.0% < 1.7% < 1.1% < 0.5% 200 µL
    825.0050 5 - 50 0.1 <± 1.5% <± 1.3% <± 1.0% < 1.0% < 0.7% < 0.4% 200 µL
    825.0100 10 - 100 0.1 <± 1.5% <± 1.2% <± 0.8% < 1.0% < 0.6% < 0.2% 200 µL
    825.0200 20 - 200 0.2 <± 1.5% <± 1.1% <± 0.6% < 0.6% < 0.4% < 0.2% 200 µL
    825.1000 100 - 1000 1 <± 1.5% <± 1.0% <± 0.5% < 0.5% < 0.4% < 0.2% 1000 µL

    Measured at 1) 0.5µL, 2) 1µL

    Performance values obtained with bi-dist. water at constant temperature
    (± 0.5°C) comprised between 20 and 25°C in accordance with ISO 8655.

    Triopack - containing three units
    Cat. No. Description Packaging
    825.TRIO.C TRIO C: 0.1 - 2 µL / 0.5 - 10 µL / 5 - 50 µL 3 pipettes/pack
    825.TRIO.J TRIO J: 0.1 - 2 µL / 2 - 20 µL / 20 - 200 µL 3 pipettes/pack
    825.TRIO.M TRIO M: 1 - 10 µL / 5 - 50 µL / 20 - 200 µL 3 pipettes/pack
    825.TRIO.O TRIO O: 0.5-10 µL / 10-100 µL / 100-1000 µL 3 pipettes/pack
    825.TRIO.P TRIO P: 1 - 10 µL / 10 - 100 µL / 100 - 1000 µL 3 pipettes/pack
    825.TRIO.S TRIO S: 2 - 20 µL / 20 - 200 µL / 100 - 1000 µL 3 pipettes/pack
    825.TRIO.T TRIO T: 5 - 50 µL / 20 - 200 µL / 100 - 1000 µL 3 pipettes/pack
    825.TRIO.V TRIO V: 10 - 100 µL / 100 - 1000 µL / 0.5 - 5 mL 3 pipettes/pack
    835.TRIO.Y TRIO Y: 100 - 1000 µL / 0.5 - 5 mL / 1 - 10 mL 3 pipettes/pack